Quality Assurance System


Vidhyut has a very stringent quality system, committed by every team member & documented as per iso-9001 QSM..

It has got a unique Three-Tier quality policy.

First all raw material including switchgear is subjected to rigorous testing.

Second-stage inspection is carried in five stages, so that every minor/major problem is eliminated & not carried further.


Third-final testing is carried out thoroughly with all calibrated instruments/gauges. The testing is done as per harmonized national & international standards including is 8623.

Tension free termination.

Each door is made out of wrinkle free sheaf & cutouts are made in fabrication stage only, to avoid life reduction of paint film. Each door is provided with concealed hinge, neoprene gasket.

Fabrication is done with gauge controlled shearing & bending and regular punching is done to provide cross punched channel for fitment of heavy components.

instruments/gauges. the testing is done as per harmonized national & international standards including is 8623.

VIDHYUT panels are manufactured in accordance with Indian & International Standards. 

We have Type tested our panels for degree of protection IP 55 tests, temperature rise tests, short circuit current withstanding tests at various laboratories in India. 

Vidhyut is registered as an approved supplier at the following organisations 

Asea Brown Boveri 
Atul Products Ltd 
Bajaj Electricals 
Bhabha Atomic Research Centre (BARC) 
Bombay Suburban Electric Supply Co. Ltd. (BSES) 
Genelec 
Larsen and Toubro 
Maharashtra State Electric Board (MSEB) 
Maharashtra State Small Industries Development Corporation (MSSIDC) 
National Dairy Development Board (NDDB) 
National Power Corporation of India Ltd. 
National Thermal Power Corporation (NTPC) 
Nestle 
Novartis 
Phillips 
Siemens 
Vizag Steel Plant 


Technical Specifications and Ratings: 

Rated Voltages:
Rated insulation voltage for factory built assembly: 660V, 40~60Hz.
Rated operational Voltage 415V, 50Hz. 
Rated Current: Main Horizontal busbars- 400A to 4000A. 
Short-circuit strength: 50KA for 1 second for busbar systems
(Type tested at Central Power Research Institute, Bhopal, India CPRI) 
Ambient temperature: Standard 40°C. optional 50°C. 
Degree of Protection: Standard IP 52. Optional IP 55
(Type tested at Controllerate of Quality Assurance Electronics, Bangalore, India CQAL)  

 